AUTOCLAVE

AUTO CLAVE DIA 1.2M

MOQ : 1 Unit

  • Chamber Size
  • Inner diameter: 1.2m, length: 2.5m
  • Chamber Thickness
  • 10-14 mm (SS316)
  • Compressed Air
  • 6-8 bar required
  • Design Pressure
  • 2.5 bar
  • Design Temperature
  • 135C
  • Door Type
  • Motorized horizontal sliding, gasket sealed
  • Heat Uniform
  • 2C through forced steam circulation
  • Inner Trolley
  • Detachable, easy-move design
  • Insulation
  • High-density mineral wool, thick outer lagging
  • Net Weight
  • Approx. 2500 kg
  • Outer Size
  • Approx. 1.8m (height) x 2.5m (width) x 3.2m (length)
  • Outer Trolley
  • Heavy-duty, stainless steel construction
  • Piping System
  • Highly durable seamless piping with safety valves and pressure indicators
  • Power Consumption
  • 8-12 kW, with stand-by mode
  • Recording Parameters
  • Temperature, Pressure, Time - digital chart recorder
  • Spraying Mode
  • Rotary or static spray (customizable)
  • Spraying Piping
  • Corrosion-resistant stainless steel, inside chamber distributed
  • Steam
  • Industrial saturated steam from steam generator/boiler
  • Sterilization Time
  • 0-120 min adjustable
  • Sterilizing Temperature
  • Up to 126C
  • Temperature Scope
  • Room temperature to 126C
  • Type
  • Other, Horizontal cylindrical autoclave
  • Valves
  • Automatic and manual safety release, steam trap valves
  • Working Pressure
  • 1.2 bar
  • Working Temperature
  • Up to 121C

AUTO CLAVE DIA 4M

MOQ : 1 Unit

  • Chamber Size
  • Diameter 4 m, Length as per requirement
  • Chamber Thickness
  • 12 mm to 25 mm depending on pressure
  • Compressed Air
  • Required for operation
  • Design Pressure
  • 2.5 bar to 3.0 bar
  • Design Temperature
  • 150C
  • Door Type
  • Horizontal cylindrical, automatically or manually operated
  • Heat Uniform
  • 2C throughout chamber
  • Inner Trolley
  • Supplied, fits chamber size
  • Insulation
  • Mineral wool/Glass wool, high thermal efficiency
  • Net Weight
  • Approx. 8 to 15 Tons
  • Outer Size
  • Dia 4 meters
  • Outer Trolley
  • Provided for easy loading/unloading
  • Piping System
  • Corrosion-resistant, heavy-duty
  • Power Consumption
  • Depends on size and installation, typically 10-20 kW
  • Recording Parameters
  • Temperature, Pressure, Time (Digital or Analog)
  • Spraying Mode
  • Multi-directional for uniform sterilization
  • Spraying Piping
  • Stainless steel spray pipes
  • Steam
  • Saturated, supplied externally
  • Sterilization Time
  • Adjustable, typically 30-60 min
  • Sterilizing Temperature
  • 121C to 134C
  • Temperature Scope
  • Ambient to 134C
  • Type
  • Other, Horizontal cylindrical steam autoclave
  • Valves
  • Multiple, stainless steel safety and control valves
  • Working Pressure
  • 2.1 bar to 2.5 bar
  • Working Temperature
  • Up to 134C


Back to top